FTX-N/U, FVXS-N, FDMQ-R Series
1
NAMES AND FUNCTIONS
"UNDER HOST COMPUTER
INTEGRATED CONTROL" LAMP
When this lamp turns on, no
other operations are possible.
GROUP NO.
ROOM NAME INDICATION
PLATE
Refer to the "2. PUTTING
ROOM NAME INDICATION
STICKER"
2
PUTTING ROOM NAME INDICATION STICKER
1
Open the upper part of remote controller.
Insert a (–) screwdriver into the recess between the upper and lower part of remote
controller (at 2 locations) and twist the screwdriver lightly.
PC board is attached both the upper and lower part of remote controller.
Do not damage the board with the screwdriver.
(–) screwdriver
(2 locations)
2
Pull out the room name indication plate.
Insert the point of a mechanical pencil etc, into the hole of the indication sticker to
pull it out.
Indication plate
3
SELECTING CONTROL MODES
The following four patterns of control mode can be set.
Control mode
Operation/stop is controlled by both
unified ON/OFF controller and
Content
remote controller.
DS2 setting
indicates the position of switches.
NOTE:
• Set control modes before turning power supply on.
• When used in conjunction with central remote controller, the control modes of the central remote controller has the priority.
4
DISPLAY OF MALFUNCTION
Flashing of lamps indicates malfunctions. Contact your Daikin dealer.
When turning power supply on, all lamps may light and UNDER HOST COMPUTER INTEGRATED CONTROL lamp may flash and not accept the operation for about on minute.
These conditions are not malfunctions.
States of lamps
Flashing of operation lamp
Flashing of UNDER HOST COMPUTER INTEGRATED CONTROL lamp
Control mode selector
(DS2)
Individual
Centralized
After operated by unified ON/OFF
controller,operation/stop is freely
controlled by remote controller until
stopped by unified ON/OFF
controller.
Indicates malfunctions in the indoor unit in the group where the operation lamp is flashing.
Indicates malfunctions in optional controllers for centralized control.
〈〈NOTE〉〉
UNIFIED OPERATION/STOP
BUTTON
● When using unified ON/OFF controller with other
Starts/stops all indoor units.
optional controllers for centralized control,
"OPERATION LAMP" of the equipment which is
not operated may turn on or off after several
minutes.
OPERATION LAMP
This state occurs due to signal communications
Turns on during operation of
and is not a failure.
each group and flashes
● Do not open the upper part of remote controller
during malfunction stop.
except when rewriting the indication sticker or
selecting control modes.
INDIVIDUAL OPERATION/
STOP BUTTON
Starts/stops each indoor unit
group individually.
3
Put the attached indication sticker on the room name indication plate.
In case of serial type
Indication sticker
Put the sticker aligning the lines of the sticker with those of the plate.
In case of individual type
Indication sticker
Put the sticker on the center of the frame.
Write the room name in the frame of the sticker with a ball point pen or a felt-tip
pen (oil-base).
Reinstall the plate as it were, with checking the correct direction.
4
5
Close the upper part of remote controller.
Timer operation possible by
remote controller
When used in conjunction with schedule
timer, operation/stop is controlled freely
by remote controller during the set time
but operation is not available when
schedule timer is ON.
Contents of malfunctions
428
EDUS091558E
Indication plate
Indication plate
ON/OFF control impossible by
remote controller
Operation/stop is controlled by
unified ON/OFF controller only.
Indoor units can not be operated/
stopped by remote controller.