Daikin FTX-N/U Manual page 311

Table of Contents

Advertisement

FTX-N/U, FVXS-N, FDMQ-R Series
Selection Settings
2
Cool
Return
Cool
Return
3
Cool
Return
01_EN_3P243520-7Q.indd 17
The icon "
" will flash on all remote controllers when the power is turned ON for the first time.
MASTER
CONTROLLED
Press
Mode button on the remote
MASTER
CONTROLLED
controller of the indoor unit which is to
Set to
74
serve as the cool/heat changeover
F
master.
Setting
The remote controller for the changeover
master indoor unit is established and the
icon is no longer displayed.
MASTER
Set to
CONTROLLED
74
Other remote controllers in the system
F
(indoor units served by the same outdoor
Setting
unit or indoor units served by the same
branch selector unit) will now display the
icon.
MASTER
CONTROLLED
Press
Mode button on the remote
controller of the indoor unit designated
Set to
74
as the cool/heat changeover master (the
F
remote controller not displaying the
Setting
icon) repeatedly until the desired
MASTER
CONTROLLED
mode is selected. The display will
change to Fan, Dry, Auto, Cool, Heat
each time the button is pressed.
Simultaneously, the other indoor units on
the system will follow suit and change
modes to re ect the new mode selected
at the changeover master remote
controller.
309
EDUS091558E
17
3P243520-7Q
3/2/2015 5:36:33 PM