FTX-N/U, FVXS-N, FDMQ-R Series
[Back piping]
2-15/16 (75)
Left back piping
About the outdoor unit refrigerant pipe
• In order to connect the pipe, the outdoor unit refrigerant pipe must have a length of at least 13-3/4 inch (350mm)
measured from the wall.
Outdoor unit refrigerant pipe
CAUTION
Minimum allowable length
• The suggested shortest pipe length is 8.2ft (2.5m), in order to avoid noise from the outdoor unit and vibration.
(Mechanical noise and vibration may occur depending on how the unit is installed and the environment in which it is used.)
• Refer to the installation manual for the outdoor unit for the maximum pipe length.
• For multi-connections, refer to the installation manual for the multi outdoor unit.