FTX-N/U, FVXS-N, FDMQ-R Series
For wired remote controller
1) Set to COOL or HEAT operation using the remote
controller.
2) Press and hold Cancel button for 4 seconds or longer.
Service settings menu is displayed.
3) Select
Test Operation
press Menu/OK button. Basic screen returns and "Test
Operation" is displayed at the bottom.
4) Press On/Off button within 10 seconds, and the test
operation starts.
Monitor the operation of the indoor unit for a minimum
of 10 minutes. During test operation, the indoor unit
will continue to cool/heat regardless of the temperature
setpoint and room temperature.
• In the case of above-mentioned procedures 3) and 4)
in reverse order, test operation can start as well.
5) Press and hold Cancel button for 4 seconds or longer in
the basic screen.
Service settings menu is displayed.
6) Select
Test Operation
press Menu/OK button. Basic screen returns and normal
operation is conducted.
• Test operation will stop automatically after 15-30
minutes. To stop the operation, press On/Off button.
01_EN_3P500432-1.indd 16
in the service settings menu, and
in the service settings menu, and
Basic screen
1)
2)
Cool
Set to
68
Cool
F
Return
Clean the filter
Service Settings
menu screen
3)
1/3
Service Settings
Test Operation
Maintenance Contact
Field Settings
Energy Saving Options
Prohibit Buttons
Min Setpoints Differential
Setting
4)
Cool
Set temperature
80
°F
Test Operation
5)
Cool
Set temperature
80
°F
Test Operation
6)
Service Settings
1/3
Test Operation
Maintenance Contact
Field Settings
Energy Saving Options
Prohibit Buttons
Min Setpoints Differential
Setting
Basic screen
125
EDUS091558E
Press and hold Cancel
button for 4 seconds or
longer during backlight lit.
Press Menu/OK button.
Press On/Off button
(within 10 seconds).
Press and hold Cancel
button for 4 seconds or
longer during backlight lit.
Press Menu/OK button.
16
3P500432-1
10/24/2017 18:32:41

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fvxs-nFdmq-r series

Table of Contents