FTX-N/U, FVXS-N, FDMQ-R Series
Water or mist comes out
Case
Mist comes out of the indoor unit�
Water is leaking from the indoor
unit
Remote controller
Case
The unit does not receive signals
from the remote controller or has
a limited operating range�
LCD is faint, is not working, or the
display is erratic�
Other electric devices start
operating�
Air has an odor
Case
The air conditioner gives off an
odor�
Others
Case
The air conditioner suddenly
starts behaving strangely during
operation�
HEAT operation cannot be
selected, even though the unit is
heat pump model�
The ON/OFF TIMER does not
operate according to the settings�
The ceiling and walls around the
indoor unit are black and dirty�
Notes on the operating conditions
• If operation continues under any conditions other than those
listed in the table,
− A safety device may activate to stop the operation.
− Dew may form on the indoor unit and drip from it when COOL
or DRY operation is selected.
01_EN_3P572320-1.indd
34
Description / what to check
• This happens when the air in the room is cooled into mist by the cold airflow during COOL
or other operation.
• If the drain hose is crushed or clogged, water from the indoor unit may be unable to drain
and start leaking. Stop operation of the unit immediately and contact your dealer.
Description / what to check
• The batteries may be exhausted.
Replace both batteries with new dry batteries AAA.LR03 (alkaline).
For details, refer to "Preparation Before Operation".
• Signal communication may be disabled if an electronic-starter-type fluorescent lamp (such
as inverter-type lamps) is in the room. Consult your dealer if that is the case.
• The remote controller may not function correctly if the transmitter is exposed to direct sunlight.
• The batteries may be exhausted.
Replace both batteries with new dry batteries AAA.LR03 (alkaline).
For details, refer to "Preparation Before Operation".
• If the remote controller activates other electric devices, move them away or consult your
dealer.
Description / what to check
• The room odor absorbed in the unit is discharged with the airflow.
We recommend you to have the indoor unit cleaned. Please consult your dealer.
• The indoor unit is blowing out room odor it has absorbed (the smell of walls or carpeting,
furniture, clothes, and so on).
If the air conditioner has been used for a long time, there is a chance that a dirty heat
exchanger or fan are emitting an odor.
We recommend you to have the indoor unit cleaned. Please consult your dealer.
Do not spray the air conditioner unit with any deodorizers.
Description / what to check
• The air conditioner may malfunction due to lightning or radio.
If the air conditioner malfunctions, turn off the power with the circuit breaker and restart the
operation with the remote controller.
• Check that the jumper (J8) has not been cut. If it
has been cut, contact your dealer.
• Check if the ON/OFF TIMER and the WEEKLY TIMER are set to the same time.
Change or deactivate the settings in the WEEKLY TIMER.
• Due to the circulation pattern of the air and static electricity, the air conditioner is causing
airborne dirt and dust to stick to walls and other surfaces. Depending on the wallpaper type,
dirt may adhere more easily. A thorough cleaning of the area around the air conditioner is
recommended.
Mode
COOL / DRY
HEAT
249
When the Need Arises
Page 9
Page 9
Jumper (J8)
Page 21
Operating conditions
Outdoor temperature: 50-115°F (10-46°C)
Indoor temperature: 64-90°F (18-32°C)
Indoor humidity: 80% max.
Outdoor temperature: 5-75°F (–15-24°C)
Indoor temperature: 50-86°F (10-30°C)
EDUS091558E
34
3P572320-1
2019/06/10
17:01:18