FTX-N/U, FVXS-N, FDMQ-R Series
Prepare the wiring for connection to the remote controller following these instructions:
Length of jacket to be removed:
Approx. 6 inch (150 mm) for top left outlet
Approx. 8 inch (200 mm) for top center outlet
Connect the terminals (P/P1, N/P2) of the remote controller to the terminals (P1, P2) of the
indoor unit. (P1 and P2 are not polarity sensitive.)
3-5-1
Back outlet
Upper case
Wire attachment
point
6
01_EN_3P243521-7L.indd 6
Remove the wire jacket
and insulation
Cutting guideline
Printed-circuit
board
Wire tie
<Wire attachment guideline>
Approx. 3/8 inch (10 mm)
To simplify the wiring, maintain
a 3/8 inch (10 mm) difference
between the length of the two
conductors.
Indoor unit
P1
P2
Lower case
Wire tie
Cross-section
Secure the wire at the
attachment point by
using furnished wire
tie.
133
EDUS091558E
-
3P243521-7L
11/27/2014 11:21:42 AM