Installation - Daikin FTX-N/U Manual

Table of Contents

Advertisement

FTX-N/U, FVXS-N, FDMQ-R Series
Indoor Unit Installation

4-2. Installation

Exposed installation
1) Secure the indoor unit
[Floor Installation]
• Secure the indoor unit using 6 screws. (2 screws for floor and 4 screws for rear wall)
2 screws
H
Indoor unit fixing screws
3/16" × 1" (M4 × 25mm)
[Wall Installation]
• Secure the
• Secure the indoor unit using 4 screws for rear wall.
5 screws
H
Indoor unit fixing screws
3/16" × 1" (M4 × 25mm)
2) Once refrigerant piping and drain piping connections are complete, fill in the gap of the through hole with putty.
Any gaps will result in the accumulation of condensation on the refrigerant pipe and drain pipe, as well as
allowing the intrusion of insects and dirt.
3) Attach the left, right and upper casings in their original
positions using 7 screws.
4) Attach the front grill in its original position using 4 screws.
5) Attach the front panel in its original position.
• Attach the string to the right, inner-side of the front grille.
• Close the front panel and slide until the 2 stoppers click
outside.
9
01_EN_3P379970-7B.indd 9
Casing
A
mounting plate using 5 screws.
A
Mounting plate
The
A
mounting
plate should be
installed on a wall
which can support
the weight of the
indoor unit.
Molding
101
4 screws
H
Indoor unit fixing screws
3/16" × 1" (M4 × 25mm)
4 screws
H
Indoor unit fixing screws
3/16" × 1" (M4 × 25mm)
Slide the stoppers
EDUS091558E
C: 3P379970-7B
11/12/2015 13:29:52

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fvxs-nFdmq-r series

Table of Contents