FTX-N/U, FVXS-N, FDMQ-R Series
14.7 <KRP067A41> Interface Adaptor for Residential Air Conditioner
Read these
installation.
Be sure to follow all the precautions below: they are all important for
ensuring safety.
Failure to follow any of WARNING is likely to result
in such grave consequences as death or serious
injury.
Failure to follow any of CAUTION may in some
cases result in grave consequences.
(Static electricity from your body can damage this set.)
(Poor wiring may cause external electrical noise.)
Installation Position
carefully to ensure correct
and CAUTION.
CAUTION
Electrical
wiring box
Installation
position
of the set
Electrical
wiring box
This set is an interface that connects a central control device to a room
air conditioner and allows you to perform the following operations, or
monitoring, in combination with the central control device using
KRP413AB1S or KRP928BB2S (sold separately).
Starting and stopping the air conditioner, and setting the mode and
temperature, through the central control device or the wired remote controller.
(64°F to 90°F (18°C to 32°C) in COOL operation, 57°F to 82°F (14°C to 28°C)
in HEAT operation, none in FAN operation)
Monitoring the operating conditions, occurrence of errors, and contents of
errors of the air conditioner through the central control device or the wired
remote controller.
Restricting the operation with a wireless remote controller found near the air
conditioner, such as starting and stopping operation, changing the mode, or
setting the temperature, through the use of the central control device, coin
timer, or card key.
Zone control through the central control device.
Restoring the operating conditions of the air conditioner to the previous
conditions at the time of power recovery in case of power outage.
This set does not support the following functions.
Group control (i.e., the control of multiple indoor units through a single
remote controller)
Monitoring of the following items: Indoor temperature and operating
management
Energy-saving command, low-noise command, and demand command
Component
Main
component
Wiring Outline
This set
Inside the indoor unit
S602
To central control
device
Option:
S21
KRP413AB1S
KRP928BB2S
S403
PCB of indoor unit
383
EDUS091558E
Quantity
Component
Quantity
Installation
1
1
Manual
S601
Note:
Wires indicated by
thick lines
are not included
with the set.
1P398933-1C

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fvxs-nFdmq-r series

Table of Contents