FTX-N/U, FVXS-N, FDMQ-R Series
11.

How to set the different addresses

• When 2 indoor units are installed in 1 room, the 2 wireless remote controllers can be set for different addresses.
Change the address setting of one of the 2 units.
When cutting the jumper be careful not to damage any of the surrounding parts.
1) Remove the electrical wiring box. (Refer to "10. When connecting to an HA system" on page 15 steps 1)-7).)
2) Cut the address jumper (JA) on the printed circuit board.
3) Cut the address jumper (J4) in the remote controller.
4) Attach the electrical wiring box as they were. (Refer to "10. When connecting to an HA system" on page 15 steps 10)-15).)
5) Attach the front panel and the front grille as they were.
01_EN_3P379970-7B.indd 16
JA ADDRESS
JA
EXIST
1
CUT
2
Side electrical
wiring box cover
Front electrical
wiring box cover
Sensor
securing plate
108
Jumper
(J8)
(J4)
J4
ADDRESS
EXIST
1
CUT
2
C: 3P379970-7B
11/12/2015 13:30:04
EDUS091558E
16