FTX-N/U, FVXS-N, FDMQ-R Series
14.16 <KRCS01-4B> Remote Sensor
Notes
Please check applicable kit model name by catalog etc.
When installed on SkyAir Round-flow type models, the dehumidification by detection of humidity does not operate.
Accessories
Check the following accessories.
Remote sensor
N
a
m
e
(sensor box)
1
Shape
Quantity
Mounting
1) Selection of mounting location.
The thermistor for temperature detection is incorporated into the remote sensor. Select the mounting location taking the
following cautions into account.
1 Where the average temperature of an air conditioned room can be detected.
2 Where it is not exposed to the direct sunlight.
3 Where it is not influenced by other heat sources.
4 Where it is not exposed to the direct discharge air from the air conditioner.
5 Where it is not exposed to the outdoor air infiltrated into the room by opening the door.
2) Mounting
Remove the cover of the sensor box.
about 6mm width
flat blade screw driver
Extension cable
(2-core, 12m)
2
3
x 1
x 1
1 Insert a flat blade screw driver into the sensor box concave part (2 locations).
2 Remove the cover pushing up the nail to the cover of the sensor box.
2
<Cautions>
Do not push the nail powerfully with a narrow flat blade screw driver,
1
because you may break off the nail.
Installation
Mounting screw
manual
C
a l
m
p
(M4x16)
(this drawing)
4
5
x 2
x 1
448
x 2
EDUS091558E
3K019189-1D