FTX-N/U, FVXS-N, FDMQ-R Series
5.
Connect the faston terminals of the drain pan heater to the terminal
block of the outdoor unit.
1) Connect the thermostat-side terminal (black harness) to the leftmost terminal and the heater-side terminal (white harness)
to the second leftmost terminal.
For type C models connect to the last terminal block of the terminal blocks in use.
2) Bundle the
Cut the tip of the
For type A models
For type B models
For type C models
6.
Install each component to the original position.
Be careful not to confuse screw types. Refer to "Installation Procedure (1) ".
1) Install the front plate.
2) Install the anti-drip cover.
(For type B and C models only)
3) Install the top plate.
Installation Procedure (5)
drain pan heater harness so that there is no slack and secure it with the
A
binding band.
C
C
Binding band
Binding band
C
View E
E
Thermostat-
side terminal
(black harness)
View E
Thermostat-
E
side terminal
(black harness)
Binding band
C
465
binding band. (1 location)
C
Heater-side
terminal
(white harness)
Heater-side
terminal
(white harness)
Heater-side terminal
(white harness)
Thermostat-side
terminal (black harness)
3P421082-1C