Terminal Function Constants: H

Multi-function Contact Inputs: H1
Con-
stant
Number
Terminal S3 func-
H1-01
tion selection
Terminal S4 func-
H1-02
tion selection
Terminal S5 func-
H1-03
tion selection
Terminal S6 func-
H1-04
tion selection
Terminal S7 func-
H1-05
tion selection
* The values in parentheses indicate initial values when initialized in 3-wire sequence.
Multi-function Contact Input Functions
Setting
Value
0
1
2
3
4
6
7
8
9
A
C
F
10
11
12
13
14
15
17
18
-26
5
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Name
Description
Multi-function contact
input 1
Multi-function contact
input 2
Multi-function contact
input 3
Multi-function contact
input 4
Multi-function contact
input 5
3-wire sequence (Forward/Reverse Run command)
Local/Remote selection (ON: Operator, OFF: Constant b1-01/b1-02 setting)
Operation Source Option Card/Inverter selection (ON: Option Card)
Multi-step speed reference 1
When H3-09 is set to 2, this function is combined with the master/auxiliary speed switch.
Multi-step speed reference 2
Jog frequency command (higher priority than multi-step speed reference)
Accel/decel time 1
External baseblock NO (NO contact: Baseblock at ON)
External baseblock NC (NC contact: Baseblock at OFF)
Acceleration/deceleration ramp hold (ON: Acceleration/deceleration stopped, frequency is hold)
Multi-function analog input A2 disable/enable (ON: Enable)
Not used (Set when a terminal is not used)
Up command (Always set with the Down command)
Down command (Always set with the Up command)
FJOG command (ON: Forward run at jog frequency d1-17)
RJOG command (ON: Reverse run at jog frequency d1-17)
Fault reset (Reset when turned ON)
Emergency stop. (NO: Deceleration to stop in deceleration time set in C1-09 when ON.)
Emergency stop (NC: Deceleration to stop in deceleration time set in C1-09 when OFF)
Timer function input (Functions are set in b4-01 and b4-02 and the timer function outputs are set in
H2-
.)
Change
during
Setting
Factory
Range
Setting
Opera-
tion
0 to 6F
24
No
0 to 6F
14
No
*
0 to 6F
No
3 (0)
*
0 to 6F
No
4 (3)
*
0 to 6F
No
6 (4)
Function
MEMO-
Access
BUS
Page
Level
Register
A
400H
A
401H
A
402H
A
403H
A
404H
Page
6-10
6-51
6-60
6-7
6-7
6-7
6-51
6-16
6-52
6-43
6-52
6-43
6-53
6-52
6-55
6-55
6-61
6-61
7-2
6-15
6-15
6-82