Selection of PI
b5-12
feedback signal
loss detection
PI feedback loss
b5-13
detection level
PI feedback loss
b5-14
detection time
Sleep function
b5-15
operation level
Sleep operation
b5-16
delay time
Accel/decel time
b5-17
for PI reference
PI Setpoint Selec-
b5-18
tion
b5-19 PI Setpoint
PI Setpoint Scal-
b5-20
ing
Sleep Function
b5-21
Selection
b5-22 Snooze Level
Snooze Delay
b5-23
Time
b5-24 Wake-Up Level
-16
5
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Name
Description
0: No detection of PI feedback
loss.
1: Detection of PI feedback loss.
Operation continues during
detection, the fault contact is not
operated.
2: Detection of PI feedback loss.
The motor coasts to stop at
detection, and the fault contact
operates.
Sets the PI feedback loss detection
level as percentage using the maxi-
mum output frequency as 100%.
Sets the PI feedback loss detection
time.
Sets the sleep function start level as
a frequency.
Sets the delay time until the sleep
function starts.
Sets the accel/decel time for the PI
Softstarter (SFS).
0: Disabled
1: Enabled
PI-target value
Sets the unit for b5-19, U1-38 and
U1-24
0: 0.01 Hz
1: 0.01% (the maximum output
frequency E1-04 is taken as
100%.
2 – 39: rpm, set value is equal to
motor poles
40 – 39999: User desired display
Sets the display value
for 100 %.
Sets the number of
decimal digits.
Sets the operation method of the PI
sleep function
0: Output frequency before Soft-
starter (SFS)
1: Frequency reference/PI target
2: Snooze
Sets the frequency level at which
the snooze operation starts as per-
centage of the max. output fre-
quency.
Sets a delay timer for the snooze
function
Sets the feedback level at which the
inverter wakes up from snooze
operation.
Change
Access
during
Setting
Factory
Range
Setting
Level
Opera-
tion
0 to 2
0
No
0 to 100
0%
No
0.0 to
1.0 s
No
25.5
0.0 to
0.0 Hz
No
200.0
0.0 to
0.0 s
No
25.5
0.0 to
0.0 s
No
25.5
0 to 1
0
No
0.00 to
100.00
0
Yes
%
0 to
0
No
39999
0 to 2
0
No
0 to
0
Yes
100%
0 to
0 s
No
3600 s
0 to 100
0
No
%
MEMO-
BUS
Page
Register
A
1B0H
6-111
A
1B1H
6-84
A
1B2H
6-84
A
1B3H
6-84
A
1B4H
6-84
A
1B5H
6-84
A
1DCH
6-84
A
1DDH
6-84
A
1E2H
6-84
A
1E3H
6-85
A
1E4H
6-85
A
1E5H
6-85
A
1E6H
6-85