YASKAWA Varispeed E7 Instruction Manual And Parameter Description page 107

Hvac frequency inverter
Hide thumbs Also See for Varispeed E7:
Table of Contents

Advertisement

Carrier Frequency: C6
Con-
stant
Number
Carrier frequency
C6-02
selection
Carrier frequency
C6-03
upper limit
Carrier frequency
C6-04
lower limit
Carrier frequency
C6-05
proportional gain
* 1. The factory setting depends on the capacity of the Inverter.
* 2. The setting range depends on the capacity of the Inverter.
* 3. This constant can be monitored or set only when C6-02 is set to F.
-20
5
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Name
Description
Selects the carrier frequency.
Select F to enable detailed settings
using constants C6-03 to C6-05.
Sets the carrier frequency upper limit
and lower limit in kHz units.
The carrier frequency gain is set as fol-
lows:
Carrier frequency
Output frequency x (C6-05) x K
(Max. output frequency)
K is a coefficient that depends on the setting
of C6-03.
C6-03 ≥ 10.0 kHz: K = 3
10.0 kHz > C6-03 ≥ 5.0 kHz: K = 2
5.0 kHz > C6-03: K = 1
Change
during
Setting
Factory
Range
Setting
Opera-
tion
6
0 to F
No
*1
2.0 to
15.0
No
15.0
kHz
*2 *3
*1
0.4 to
15.0
No
15.0
kHz
*2 *3
*1
Output
frequency
00 to
00
No
99
*3
MEMO-
Access
BUS
Page
Level
Register
4-5
Q
224H
4-11
6-2
A
225H
6-2
A
226H
6-2
A
227H
6-2

Advertisement