Writing Constant Set Values Stored in the Digital Operator to the Inverter (COPY)
To write constant set values stored in the Digital Operator to the Inverter, use the following method.
Step
Digital Operator Display
No.
1
2
3
4
5
6
7
If an error is displayed, set the constants again. Error displays and their meanings are shown below. (Refer to
Chapter 7 Errors when Using the Digital Operator Copy
Error Display
Inverter product code or Inverter software number are different.
Inverter capacity with which you are trying to copy, and the Inverter capacity stored in the Digital
Operator are different.
Comparison between the constant written to the Inverter and the constant in the Digital Operator are
different.
After copying has ended, comparison between the checksum value of the Inverter constant area and
the checksum value of the Digital Operator constant area are different.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Table 6.3 COPY Function Procedure
Function.)
Meaning
Digital Operator Functions
Explanation
Press the MENU key, and select advanced pro-
gramming mode.
Press the DATA/ENTER key to enter the pro-
gramming mode.
Select constant o3-01 (Copy Function Selec-
tion) using the Increment key and Decrement
key.
Press the DATA/ENTER key to enter the con-
stants setting display.
Change the set value to 2 using the Increment
key.
Press the DATA/ENTER key. The COPY func-
tion will start.
If the COPY function ends normally, "End" is
displayed on the Digital Operator. Constant
o3-01 is automatically reset to 0, and then the
display returns to o3-01.