Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Table 7.5 Errors during Copy Function
Meaning
Probable causes
The Inverter product code or software
number is different.
The capacity of the Inverter being
copied and the capacity stored in the
Digital Operator are different.
The control method of the Inverter
being copied and the control method
in the Digital Operator are different.
The constant written to the Inverter
was compared with the constant in the
Digital Operator and they were differ-
ent.
The checksum in the Inverter constant
area was compared with the checksum
in the Digital Operator constant area
and they were different.
The settings in the operator and the
inverter do not match.
Protective and Diagnostic Functions
Corrective Actions
Use the copy function for the same
product code and software number
only.
Use the copy function for the same
Inverter capacity only.
Use the copy function for the same
control method only.
Retry the copy.