Adapting The Settings Of The F-Runtime Group (Optional) - Siemens SINUMERIK MC Commissioning Manual

Safety integrated (with sinamics s120)
Hide thumbs Also See for SINUMERIK MC:
Table of Contents

Advertisement

Commissioning and configuring
6.3 Generating a safety program
Result
The F-capable PLC variables have been created.
Figure 6-4
Example: Variable table
6.3.3

Adapting the settings of the F-runtime group (optional)

You can find the associated F-blocks of an F-runtime group in folder "Program blocks" or in the
Safety Administration Editor under "F-blocks":
● FOB_RTG1[OB123]
● Main_Safety [FB1010]
● Main_Safety_DB [DB1010]
You can adapt the default settings of the F-runtime group and the associated blocks, as
described here.
Optionally, you can also create a second F-runtime group; for example, to organize safety-
relevant program sections that are executed quickly, in their own dedicated F-runtime group.
Precondition
● Safety Integrated is active
232
Safety Integrated (with SINAMICS S120)
Commissioning Manual, 02/2020, A5E46305916B AB