Siemens SINUMERIK MC Commissioning Manual page 395

Safety integrated (with sinamics s120)
Hide thumbs Also See for SINUMERIK MC:
Table of Contents

Advertisement

Data areas
The following data areas are backed up in a commissioning archive:
Components
NC data
PLC data
Drive data
Programs on a local
drive/NCextend
For NC data, only the deviations from the standard default values are backed up. Machine data
1)
MD11210 $MN_UPLOAD_MD_CHANGES_ONLY and MD11212 $MN_UPLOAD_CHANGES_ONLY
do not influence the archive content.
The scope of data will be individualized in future software versions.
2)
Safety Integrated (with SINAMICS S120)
Commissioning Manual, 02/2020, A5E46305916B AB
A.4 Data backup and archiving in the SINUMERIK ONE Commissioning Tool
Data
Machine data
1)
Setting data
Option data
Global user data (GUD)
Tool and magazine data
Protection zone data
R parameters
Zero offsets
Workpieces, part programs and subprograms
Manufacturer cycles
User cycles
Definitions and macros
Collision avoidance data
Compensation data
● QEC - quadrant error compensation
● CEC - operation/angularity compensation
● EEC - leadscrew pitch / encoder error compensation
Note: It only makes sense to archive machine-specific
compensation data if the series commisioning file is reloa‐
ded into the same control.
Axis optimization data (AST)
Compile cycles
PLC project
Remanence data
Drive data archiving
Programs contained in the user memory area.
Note: Because the user data can become very large, the
created archive file may require more storage.
The content is only backed up if it does not exceed 1 GB.
Appendix
Backup
Setup
2)