Sca - Siemens SINUMERIK MC Commissioning Manual

Safety integrated (with sinamics s120)
Hide thumbs Also See for SINUMERIK MC:
Table of Contents

Advertisement

Commissioning and configuring
6.6 Configuring safety functions integrated in the drive
6.6.13

SCA

Precondition
● The Safety Integrated commissioning mode (Page 249) is active for the drive to be
configured.
● The drive is configured for operation with an encoder and Extended Functions.
Display "SI Safe Cams" commissioning screen
MENU SELECT > Commissioning > Menu forward key > Safety > Functions > SCA
Figure 6-31
Settings
Setting
Modulo value SP
p9505
SCA function
296
Safe Cams - SCA
Meaning
Sets the modulo value in degrees for rotary axes for the "Safe position"
function.
This modulo value is taken into account for safe referencing and for the
transfer of the safe position via PROFIsafe when absolute position is ena‐
bled.
Inhibits or enables the SCA function throughout.
Safety Integrated (with SINAMICS S120)
Commissioning Manual, 02/2020, A5E46305916B AB