Siemens SINUMERIK MC Commissioning Manual page 265

Safety integrated (with sinamics s120)
Hide thumbs Also See for SINUMERIK MC:
Table of Contents

Advertisement

Softkey
Drive +
Drive -
Select a drive
Recommended values
Making the settings
Table 6-8
Setting
Enable SIC/SCC
SIC/SCC module number
Telegram configuration
Table 6-9
Setting
PROFIsafe address
Telegram configuration
Safety parameter assign‐
ment
Stop response for PROFI‐
safe communication failure
Safety Integrated (with SINAMICS S120)
Commissioning Manual, 02/2020, A5E46305916B AB
Purpose
The settings are specific to a certain drive. Switch to the corresponding drive using the appro‐
priate softkey before configuring.
Using softkey "Recommended values", you can automatically preassign the values of the par‐
ticular startup screen form.
For example, in the startup screen form "Telegram configuration", the telegram types from the
configuration belong to the settings that can be assigned as default.
Check the individual suggested values.
SIC/SCC telegram settings (Settings - telegram configuration)
Meaning
Enables/inhibits the evaluation of the Safety Info Channel/Safety Control
Channel (SIC/SCC).
This option is automatically activated when setting the function scope
(Page 251).
Sets the SIC/SCC module number.
Sets the telegram type for the Safety Info Channel (SIC)/Safety Control
Channel (SCC).
PROFIsafe telegram settings (Settings - telegram configuration)
Meaning
Sets the PROFIsafe address for the Control Unit.
Sets the PROFIsafe telegram type.
Sets the PROFIsafe telegram type for the Control Unit.
Setting the stop response in case of failure of the PROFIsafe communi‐
cation
Commissioning and configuring
6.5 Configuring NC and drive-specific safety settings