G Function Groups - Siemens SINUMERIK 828D Programming Manual

Hide thumbs Also See for SINUMERIK 828D:
Table of Contents

Advertisement

16.4

G function groups

The G functions are divided into function groups. Only one G function of a group can be
programmed in a block. A G function can be either modal (until it is canceled by another
function of the same group) or only effective for the block in which it is programmed (non-
modal)
Key:
1)
2)
3)
4)
5)
Fundamentals
Programming Manual, 07/2010, 6FC5398-1BP40-0BA0
Internal number (e.g. for PLC interface)
Configurability of the G function as a delete setting for the function group on power up,
reset or end of part program with MD20150 $MC_GCODE_RESET_VALUES:
+
Configurable
-
Not configurable
Effectiveness of the G function:
m
modal
n
non-modal
Default setting
If no function from the group is programmed with modal G functions, the default setting,
which can be changed in the machine data
(MD20150 $MN_$MC_GCODE_RESET_VALUES), applies:
SAG Default setting Siemens AG
MM
Default setting Machine Manufacturer (see machine manufacturer's
specifications)
The G function is not valid for NCU571.