11.02
Remedy:
Program Continuation:
10654
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
10655
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
10656
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
10700
Parameters:
Definitions:
 Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
Please inform the authorized personnel/service department.
1. Check axis (uneven mechanical movement?)
2. MD not set correctly (MD 37120 GANTRY_POS_TOL_ERROR). A POWER ON is nec-
essary after modifying the MD.
If the axes are not yet referenced, MD GANTRY_POS_TOL_REF is the trigger condition
for the error message.
Clear alarm with the RESET key. Restart part program
Channel %1 waiting for synchronization start of gantry group %2
%1 = Channel number
%2 = Gantry unit
Alarm message appears when the axes are ready for synchronization. The gantry unit
can now be synchronized. The actual value difference between master and slave axis is
greater than the gantry warning threshold MD 37110 GANTRY_POS_TOL_WARNING.
The synchronization must be started again explicitly with the start gantry synchronization
interface signal (DB31-48, DBX 29.4).
- Alarm display.
Please inform the authorized personnel/service department. See Description of Functions
(Special Functions), G1 Gantry Axis
Alarm display showing cause of alarm disappears. No further operator action
Channel %1 synchronization of gantry group %2 in progress
%1 = Channel number
%2 = Gantry unit
No further explanation.
- Alarm display.
-
Alarm display showing cause of alarm disappears. No further operator action
Channel %1 axis %2 gantry alarm not yet used
%1 = Channel number
%2 = Axis
No further explanation. Spare alarm, not used at the present time.
- NC Start disable in this channel.
- Alarm display.
- Interface signals are set.
- NC Stop on alarm.
- If the axis is a single axis when this alarm is triggered, the alarm is only effective for this
axis (not effective for e.g. the channel or mode group)
-
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 NCK protection zone %3 violated during automatic or MDA
mode
%1 = Channel number
%2 = Block number
%3 = Protection zone number
The workpiece-related NCK protection zone has been violated. Note that another tool-
related protection zone is still active. The workpiece-related protected area can be tra-
versed after a new NC Start.