11.02
Remedy:
Program Continuation:
120005
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
120006
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
120007
Definitions:
Reactions:
Remedy:
Program Continuation:
120008
Definitions:
Reactions:
Remedy:
Program Continuation:
120120
Parameters:
Definitions:
 Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
Try again and, if possible, close the reluctant area first.
Internal
Please acknowledge the dialog box in area %1
%1 = Operating area name
The area %1 could not be deselected, as in this area a dialog box is still open.
- Alarm display.
Close the dialog box in area %1!
Internal
The channel switchover is currently disabled by area %1.
%1 = Operating area name
The area %1 has disabled the channel switchover at the moment, as it is performing a
critical operation (e.g. execution from external sources, etc.), during which no channel
switchover may occur.
- Alarm display.
Wait until the critical operation is finished or end the critical operation manually.
Internal
The channel switchover is currently disabled.
The channel switchover is currently disabled, as a critical operation, during which no
channel switchover may occur, is being carried out.
- Alarm display.
Wait until the critical operation is finished or end the critical operation manually.
Internal
Control unit switchover, PLC timeout: 001 control unit switchover, PLC timeout:
002 control unit switchover, PLC timeout: 003
• 001: MMC would like to go offline from this NCU. MMC has made the offline request in
the online PLC and is waiting for the positive / negative acknowledgement from the
PLC.
• 002: MMC would like to go online to this NCU. MMC has called the target PLC and is
waiting for the release to go online.
• 003: MMC has requested the active operating mode and is waiting for acknowledge-
ment from the PLC.
- -
Check whether the switchover blocks are loaded and started in the online PLC.
Internal
The alarm list is full of alarm texts: Number of alarm texts too high Alarm texts: File
%1 not found alarm texts: Input/Output error in file %1 alarm texts: Input/Output
error alarm texts: Error when reading from the index file alarm texts: Error when
writing in the index file alarm texts: Syntax error in alarm text file %1
%1 = File name
Alarm text: Alarm list is full.
• Pending alarms/messages could not be entered into the alarm list due to lack of space.
The alarm cannot be deleted, as this event has made the alarm list permanently incon-
sistent.