11.02
4170
Definitions:
Reactions:
Remedy:
Program Continuation:
4180
Definitions:
Reactions:
Remedy:
Program Continuation:
4181
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
 Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
Invalid M function number for channel synchronisation assigned
An M number between 0 and 99 has been specified In machine data
$MN_EXTERN_CHAN_SYNC_M_NR_MIN or
$MN_EXTERN_CHAN_SYNC_M_NR_MAX for the configuration of the M number range
for channel synchronization in ISO2/3 mode or the machine data
$MN_EXTERN_CHAN_SYNC_M_NR_MAX is smaller than
$MN_EXTERN_CHAN_SYNC_M_NR_MIN.
- Alarm display.
- Interface signals are set.
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- NC Stop on alarm.
Check machine data $MN_EXTERN_CHAN_SYNC_M_NR_MIN and
$MN_EXTERN_CHAN_SYNC_M_NR_MAX.
Switch control OFF - ON.
Invalid M function number assigned to enable ASUP
An invalid M function number has been assigned for activation of ASUP. An illegal M
number has been assigned in machine data $MN_EXTERN_M_NO_SET_INT or
$MN_EXTERN_M_NO_DISABLE_INT for the configuration of the M number range for
activation/deactivation of the interrupt program.
- Alarm display.
- Interface signals are set.
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- NC Stop on alarm.
Check machine data $MN_EXTERN_ M_NO_SET_INT and
$MN_EXTERN_M_NO_DISABLE_INT.
Switch control OFF - ON.
Channel %1 invalid assignment of an M auxiliary function number
%1 = Channel number
In machine data $MC_AUXFU_ASSOC_M0_VALUE or
$MC_AUXFU_ASSOC_M1_VALUE, a number has been specified for the configuration of
a new predefined M function which is occupied by the system, and cannot be used for an
assignment. (M0 to M5, M17, M30, M40 to M45).
- Alarm display.
- Interface signals are set.
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- NC Stop on alarm.
Configure an M function in machine data $MC_AUXFU_ASSOC_M0_VALUE or
$MC_AUXFU_ASSOC_M1_VALUE which is not occupied by the system (M1 to M5, M17,
M30, M40 to M45).
Switch control OFF - ON.