11.02
Program Continuation:
16200
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
16300
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
16400
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
16410
Parameters:
Definitions:
 Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 spline and polynominal interpolation not available
%1 = Channel number
%2 = Block number, label
The spline and polynomial interpolation are options that are not contained in the basic
version of the control.
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
Do not program spline and polynomial interpolation, or retrofit the necessary option.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 denominator polynominal with zero places within parameter
range not allowed
%1 = Channel number
%2 = Block number, label
The programmed denominator polynomial (with PL [ ] = ... , i.e. without specification of
geometry axis) has a zero place within the defined parameter range (PL = ...). This means
that the quotient of the numerator polynomial and the denominator polynomial is infinite or
indeterminate.
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
Modify the polynomial block so that there is no zero place within the polynomial length in
the denominator polynomial.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 positioning axis %3 cannot participate in spline
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
An axis assigned to a spline grouping (n) with SPLINEPATH (n, AX1, AX2, ...) has been
programmed as positioning axis with POS or POSA.
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
Do not assign the positioning axis to the spline grouping.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 axis %3 is not a geometry axis
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
A geometry axis has been programmed that cannot be imaged on any machine axis in the
current transformation (possibly there is no transformation active at the moment).
Example:
Without transformation: Polar coordinate system with X, Z, and C axis