Siemens SINUMERIK 840D Series Diagnostics Manual page 161

Hide thumbs Also See for SINUMERIK 840D Series:
Table of Contents

Advertisement

11.02
Definitions:
Reactions:
Remedy:
Program Continuation:
14030
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14033
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14034
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14035
Parameters:
 Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
An FCTDEF command was programmed with a polynomial number that exceeds the
maximum value set in $MC_MM_NUM_FCTDEF_ELEMENTS.
- Alarm display.
- Interface signals are set.
- Interpreter stop
- NC Start disable in this channel.
Modify part program.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 combine OSCILL and POSP during oscillation with infeed
motion
%1 = Channel number
%2 = Block number, label
When oscillating controlled by synchronized actions, the assignment of oscillating and
infeed axis (OSCILL) as well as the definition of the infeed (POSP) must be carried out in
one NC block.
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
Modify part program.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 involute: no end point programmed
%1 = Channel number
%2 = Block number, label
No end point was programmed for the involute. This is either possible via direct program-
ming with the geometry axis identifiers or by specifying the angle between start and end
vector.
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
Modify part program.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 involute: angle of rotation too large
%1 = Channel number
%2 = Block number, label
With programming of the angle of rotation (with AR) for involute interpolation, the maxi-
mum programmable angle of rotation is limited if the involute is moving towards the basic
circle. The maximum value is reached if the involute touches the basic circle. With
MD_INVOLUTE AUTO_ANGLE_RESTRICTION = TRUE, each angle is accepted without
an alarm; if necessary, the angle is automatically limited during interpolation.
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
Modify part program.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 involute: start point invalid
%1 = Channel number
%2 = Block number, label
1 Alarms