11.02
Remedy:
Program Continuation:
14753
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14754
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14755
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14756
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
 Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
The functions DELDTG and STOPREOF exclude each other in a block.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 motion synchronous actions with illegal interpolation type
%1 = Channel number
%2 = Block number, label
The active interpolation type (e.g. 5-axis interpolation) is not allowed for the motion syn-
chronous action or for the function "Several feeds".
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
Modify part program.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 motion synchronous actions and wrong feed type
%1 = Channel number
%2 = Block number, label
The active feed type is not allowed for the motion synchronous action or for the function
"Several feeds".
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
Modify part program.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 motion synchronous actions without traverse motion
%1 = Channel number
%2 = Block number, label
The programmed motion synchronous action and the function "Several feeds" require a
traversing motion or the value of the traversing motion is 0.
This alarm is no longer used after P3.2.
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
Modify part program.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 motion synchronous action and wrong value
%1 = Channel number
%2 = Block number, label
Value of the synchronous action or the function "Several feeds" is not allowed.
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Modify part program. Check whether a negative value was entered for a synchronous
action.
Clear alarm with NC START or RESET key and continue the program.