Siemens SINUMERIK 840D Series Diagnostics Manual page 517

Hide thumbs Also See for SINUMERIK 840D Series:
Table of Contents

Advertisement

11.02
Program Continuation:
300768
Parameters:
Definitions:
Reactions:
Remedy:
 Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
• Modify MD 1520: $MD_SPEED_FILTER_1_BS_FREQ (bandstop filter natural fre-
quency speed setpoint filter 1)
• Modify MD 1514: $MD_SPEED_FILTER_1_SUPPR_FREQ (suppression frequency
speed setpoint filter 1) 1)
• Modify MD 1521: $MD_SPEED_FILTER_2_BS_FREQ (bandstop filter natural fre-
quency speed setpoint filter 2)
• Modify MD 1517: $MD_SPEED_FILTER_2_SUPPR_FREQ (suppression frequency
speed setpoint filter 2) 2)
• Modify MD 1001: $MD_SPEEDCTRL_CYCLE_TIME (speed controller cycle)
Clear alarm with the RESET key in all channels. Restart part program.
Axis %1 drive %2 numerator bandwidth > double blocking frequency
%1 = NC axis number
%2 = Drive number
The bandwidth numerator of a current or speed setpoint filter is greater than twice the
blocking frequency.
This error message is only issued for the general bandstop filter if:
• Speed setpoint filter 1:
• MD 1516 > 0.0 or
• MD 1520 <> 100.0
• Speed setpoint filter 2:
• MD 1519 > 0.0 or
• MD 1521 <> 100.0
• Current setpoint filter 1:
• MD 1212 > 0.0
• Current setpoint filter 2:
• MD 1215 > 0.0
• Current setpoint filter 3:
• MD 1218 > 0.0
• Current setpoint filter 4:
• MD 1221 > 0.0
The alarm can be reprogrammed in the MD ALARM_REACTION_CHAN_NOREADY
(channel not ready).
- NC not ready.
- Channel not ready.
- Channel not ready.
- NC Stop on alarm.
- NC Start disable in this channel.
- The NC switches to follow-up mode.
- Alarm display.
- Interface signals are set.
Please inform the authorized personnel/service department.
The bandwidth numerator must be less than twice the blocking frequency.
• Current setpoint filter 1:
• MD 1212 <= 2 * MD 1210
• Current setpoint filter 2:
• MD 1215 <= 2 * MD 1213
• Current setpoint filter 3:
• MD 1218 <= 2 * MD 1216
• Current setpoint filter 4:
• MD 1221 <= 2 * MD 1219
1 Alarms
1-517

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840di seriesSinumerik 810d seriesSinumerik 840dSinumerik 840diSinumerik 810dSinumerik 840de ... Show all

Table of Contents