11.02
20053
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
20054
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
20055
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
 Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
Channel %1 axis %2 DRF, FTOCON, external zero point offset not possible
%1 = Channel number
%2 = Axis name, spindle number
The axis is traversed in a mode (e.g. referencing) that allows no additional overlaid inter-
polation.
- Alarm display.
Wait until the axis has reached its reference position or terminate reference point
approach with "Reset" and start DRF once again.
Clear alarm with the Delete key or NC START.
Channel %1 axis %2 wrong index for indexing axis in JOG mode
%1 = Channel number
%2 = Axis name, spindle number
1. The displayed indexing axis is to be traversed incrementally in JOG mode (by 1 index-
ing position). However, no further indexing position is available in the selected direction.
2. The axis is stationary at the last indexing position. In incremental traversing the working
area limitation or the software limit switch is reached without an indexing position being
located in front of it at which a stop could be made.
- Alarm display.
Please inform the authorized personnel/service department.
Correct (add to) the list of indexing positions by means of the machine data
Modify MD 10900: INDEX_AX_LENGTH_POS_TAB_1
Modify MD 10910: INDEX_AX_POS_TAB_1
Modify MD 10920: INDEX_AX_LENGTH_POS_TAB_2
Modify MD 10930: INDEX_AX_POS_TAB_2
or set the working area limits or the software limit switches to other values.
Clear alarm with the Delete key or NC START.
Channel %1 master spindle not present in JOG mode
%1 = Channel number
The displayed axis is to be traversed as machine axis in JOG mode with revolutional feed,
but no master spindle has been defined from which the actual speed could have been
derived.
- Alarm display.
- Interface signals are set.
- Local alarm reaction.
Please inform the authorized personnel/service department. If the revolutional feed is also
to be active in JOG mode, then a master spindle must be declared via the channel-spe-
cific machine data 20090 SPIND_DEF_MASTER_SPIND. In this case you have to open a
screen in the PARAMETER operating area with the soft keys "SETTINGDATA" and "JOG
DATA" and preselect the G function G95 there. The JOG feedrate can then be entered in
[mm/rev]. (If 0 mm/rev is set as JOG feed, the control takes the value assigned in the axis-
specific MD 32050 JOG_REV_VELO or in the case of rapid traverse overlay 32040
JOG_REV_VELO_RAPID).
The revolutional feed in JOG mode is deactivated by changing the G function from G95 to
G94.
Clear alarm with the Delete key or NC START.