Siemens SINUMERIK 840D Series Diagnostics Manual page 261

Hide thumbs Also See for SINUMERIK 840D Series:
Table of Contents

Advertisement

11.02
17194
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
17200
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
17202
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
 Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
Channel %1 block %2 no suitable tool found
%1 = Channel number
%2 = Block number, label
• An attempt was made to access a tool which has not been defined.
• The specified tool does not permit access.
• A tool with the desired properties is not available.
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
Check access to tool:
• Are the parameters of the command correctly programmed?
• Does the status of the tool prevent access?
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 deleting tool data not possible
%1 = Channel number
%2 = Block number, label
An attempt has been made to delete from the part program the tool data for a tool cur-
rently being processed. Tool data for tools involved in the current machining operation
may not be deleted. This applies both for the tool preselected with T or that has been
changed in place of another, and also for tools for which the constant grinding wheel
peripheral speed or tool monitoring is active.
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
Check access to tool offset memory by means of $TC_DP1[t,d] = 0 or deselect tool.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 deleting magazine data not possible
%1 = Channel number
%2 = Block number, label
An attempt was made to delete magazine data which cannot currently be deleted. A mag-
azine with the 'tool in motion' status active cannot be deleted. A tool adapter which is cur-
rently allocated to a magazine location cannot be deleted. A tool adapter cannot be
deleted if machine data $MN_MM_NUM_TOOL_ADAPTER has the value -1.
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
If an attempt to delete a magazine fails
$TC_MAP1[ m ] = 0 ; Delete magazine with m=magazine no.
$TC_MAP1[ 0 ] = 0 ; Delete all magazines
$TC_MAP6[ m ] = 0 ; Delete magazines and all their tools you must ensure that the mag-
azine does not have the 'tool in motion' status at the time of the call.
If an attempt to delete a tool adapter fails
$TC_ADPTT[ a ] = -1 ; Delete adapter with number a
$TC_ADPTT[ 0 ] = -1 ; Delete all adapters
then the data association with the magazine location or locations must first be canceled
with $TC_MPP7[ m,p ] = 0 ; m = magazine no., p = no. of the location to which the adapter
is assigned.
Clear alarm with NC START or RESET key and continue the program.
1 Alarms
1-261

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840di seriesSinumerik 810d seriesSinumerik 840dSinumerik 840diSinumerik 810dSinumerik 840de ... Show all

Table of Contents