Siemens SINUMERIK 840D Series Diagnostics Manual page 488

Hide thumbs Also See for SINUMERIK 840D Series:
Table of Contents

Advertisement

1 Alarms
Program Continuation:
300611
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
300612
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
300613
Parameters:
1-488
Clear alarm with the RESET key in all channels of this mode group. Restart part program.
Axis %1 drive %2 generator mode: Motion at rotor position identification
%1 = NC axis number
%2 = Drive number
During the measurement, the motor has turned by more than the permissible value
entered in MD1020: $MD_MAX_TURN_ROTORPOS_IDENT (maximum rotation of the
rotor position identification). The rotation can be caused by switching on a rotating motor
or by the identification itself.
The alarm can be reprogrammed in the MD ALARM_REACTION_CHAN_NOREADY
(channel not ready).
- Mode group not ready.
- Channel not ready.
- Channel not ready.
- NC Start disable in this channel.
- NC Stop on alarm.
- The NC switches to follow-up mode.
- Alarm display.
- Interface signals are set.
Please inform the authorized personnel/service department.
• If the rotation was caused by the identification itself, and if the error occurs repeatedly,
then reduce MD1019: $MD_CURRENT_ROTORPOS_IDENT or increase MD1020:
$MD_MAX_TURN_ROTORPOS_IDENT (maximum rotation of the rotor position identi-
fication).
• Brake the motor during the identification.
Clear alarm with the RESET key in all channels of this mode group. Restart part program.
Axis %1 drive %2 illegal current during rotor position identification
%1 = NC axis number
%2 = Drive number
1. With rotor position identification active, the current was
>= 1.2 * 1.05 * INVERTER_MAX_CURRENT (MD 1107)
2. With rotor position definition active, the current was
>= MOTOR_MAX_CURRENT (MD 1104)
- Mode group not ready.
- Channel not ready.
- Channel not ready.
- NC Start disable in this channel.
- NC Stop on alarm.
- The NC switches to follow-up mode.
- Alarm display.
- Interface signals are set.
Please inform the authorized personnel/service department. Check MD 1019 with rotor
position identification active and, if necessary, reduce the setting.
Clear alarm with the RESET key in all channels of this mode group. Restart part program.
Axis %1 drive %2 maximum permissible motor temperature exceeded
%1 = NC axis number
%2 = Drive number
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
 Siemens AG, 2002. All rights reserved
11.02

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840di seriesSinumerik 810d seriesSinumerik 840dSinumerik 840diSinumerik 810dSinumerik 840de ... Show all

Table of Contents