Siemens SINUMERIK 840D Series Diagnostics Manual page 63

Hide thumbs Also See for SINUMERIK 840D Series:
Table of Contents

Advertisement

11.02
6405
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
 Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
Channel %1 command %2 has invalid PLC acknowledge parameter %3 - identifier
%4
%1 = Channel ID
%2 = Command no.
%3 = PLC acknowledge parameter
%4 = Error code
The specified command has been answered by PLC with an invalid acknowledgement in
the current combination. The following assignments are defined for "command no.":
1 Move tool, load or unload magazine
2 Prepare tool change
3 Execute tool change
4 Prepare tool change and execute with T command
5 Prepare tool change and execute with M command
7 Terminate canceled tool command
8 Check tool movement with reservation
9 Check tool movement
0 Transport acknowledgement
Parameters 2 and 3 designate the PLC command and the status number of the acknowl-
edgement.
Example: Parameter 4 of the alarm message is 10. It is not defined whether a buffer loca-
tion for asynchronous tool motion must be reserved. In the example, the parameter is
ignored by the NCK. Further possible causes for the alarm: The tool change defined by
the command is not possible. The magazine location specified in the invalid parameter
does not exist in the magazine.
The 3rd parameter - error identification - gives a more detailed description of the alarm.
Meanings:
• 0 = not defined
• 1 = status not allowed or undefined status received by PLC
• 2 = source and/or target magazine no./location no. unknown
• 3 = not defined
• 4 = target magazine no. and/or location no. in tool motion command not end target
• 5 = not defined
• 6 = source and/or target magazine no./location no. unknown during tool change
• 7 = PLC comm. with inconsistent data: either inconsistent magazine addresses in VDI
or NCK command unequal to PLC acknowledgement or both
• 8 = PLC comm. with inconsistent data: while rejecting a tool, the tool to be rejected was
unloaded asynchronously. NCK cannot perform a new selection.
• 9 = PLC comm. with inconsistent data: the command acknowledgement data wants to
move a tool to a location that is occupied by another tool.
• 10 = it is not defined whether a buffer location for asynchronous tool motion must be
reserved.
- Alarm display.
- Interface signals are set.
- NC Start disable in this channel.
- NC Stop on alarm.
Please inform the authorized personnel/service department. Erroneous PLC communica-
tion: Correct the PLC program.
Clear alarm with the RESET key. Restart part program
1 Alarms
1-63