Siemens SINUMERIK 840D Series Diagnostics Manual page 38

Hide thumbs Also See for SINUMERIK 840D Series:
Table of Contents

Advertisement

1 Alarms
4060
Definitions:
Reactions:
Remedy:
Program Continuation:
4062
Definitions:
Reactions:
Remedy:
Program Continuation:
4065
Definitions:
Reactions:
Remedy:
Program Continuation:
4066
Definitions:
Reactions:
Remedy:
Program Continuation:
1-38
Standard machine data loaded
With the next system power-up, the standard MDs are loaded by the system-specific MD
11200 INIT_MD if
• MD buffer voltage has failed or
• after initialization for loading the standard machine data.
- Alarm display.
Please inform the authorized personnel/service department. After automatically loading
the standard MDs, the individual MDs must be entered or loaded in the relevant system.
Clear alarm with the RESET key. Restart part program
Backup data loaded
The user data saved in the flash memory are loaded to the SRAM.
- Alarm display.
Please inform the authorized personnel/service department. Load specific machine data
again.
Clear alarm with the RESET key. Restart part program
Buffered memory was restored from backup medium (potential loss of data!)
Only occurs with PC-NC. A possible data integrity error was detected in the buffered
memory during power-up. The buffered memory was initialized with the last backup copy.
Changes in the buffered memory, which have been made since the last backup copy
update, have been lost. Backup copies of the buffered memory are updated (on the hard
disk) every time the control is shut down normally.
!! Only for 802D: The reason for this procedure is that the backup time is exceeded. Make
sure that the required operating time of the control corresponds to the specifications in
your Installation & Start-up Guide. The current backup copy of the buffered memory has
been created by the last internal data backup via the "Save data" soft key on the HMI.
- Alarm display.
- Interface signals are set.
- NC not ready.
- NC Start disable in this channel.
Start the control again.
Switch control OFF - ON.
Buffered memory of FFS restored from backup medium (potential loss of data!)
For PC-NC: A possible data integrity error was detected in the FFS memory during
power-up. The FFS memory was initialized with the last backup copy. Changes in the
FFS memory, which have been made since the last backup copy update, have been lost.
!! Only for PC-NC: Backup copies of the buffered memory are updated (on the hard disk)
every time the control is shut down normally.
- Alarm display.
- Interface signals are set.
- NC not ready.
- NC Start disable in this channel.
Start the control again.
Switch control OFF - ON.
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition