1 Alarms
Reactions:
Remedy:
Program Continuation:
15160
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
15165
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
15166
Parameters:
Definitions:
Reactions:
1-210
- Alarm display.
- Interface signals are set.
- Interpreter stop
- NC Start disable in this channel.
Insert machine function blocks in the part program.
• Increase the size of the reload buffer ($MN_MM_EXT_PROG_BUFFER_SIZE).
• Decrease the size of the curve table (Note: Blocks within CTADDEF/CTABEND are not
machine function blocks).
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 wrong preprocessing configuration
%1 = Channel number
%2 = Block number, label
The following deadlock has been found in the interpreter: A block element is needed but
the block element memory is empty and there is no likelihood of getting new block ele-
ments by processing the preprocessing/main run queue because this queue itself is
empty.
- Alarm display.
- Interface signals are set.
- Interpreter stop
- NC Start disable in this channel.
Please inform the authorized personnel/service department. Modify the block search con-
figuration in machine data 28060 MM_IPO_BUFFER_SIZE (decrease size of IPO buffer if
necessary) or 28070 MM_NUM_BLOCKS_IN_PREP.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 error when translating or interpreting PLC Asup %3
%1 = Channel number
%2 = Block number, label
%3 = String
At part program start, the data part of the selected PLC Asup is conditioned. If an error
occurs (translator or interpreter) first this alarm is output and then a translator or inter-
preter alarm that describes the error in more detail. The error causes the interpreter to
stop. Correction block is not possible.
- Alarm display.
- Interface signals are set.
- Interpreter stop
- NC Start disable in this channel.
Modify part program.
Clear alarm with the RESET key. Restart part program
Channel %1 user system asup _N_ASUP_SPF not available
%1 = Channel number
By means of the machine data 11610 $MN_ASUP_EDITABLE the function "User-defined
system asup" has been activated. However, the relevant user program could not be found
in the specified search path:
• 1. /_N_CUS_DIR/_N_ASUP_SPF
• 2. /_N_CUS_DIR/_N_ASUP_SPF
The default system asups are used.
- Alarm display.
- Interface signals are set.
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
 Siemens AG, 2002. All rights reserved