11.02
6692
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
6693
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
6698
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
6700
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
7000
Definitions:
Reactions:
Remedy:
Program Continuation:
 Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
Cycle %1 lost
%1 = Name of cycle
A cycle has been changed and due to a power failure, the backup on the PC card could
not be terminated properly. The cycle is lost.
- Alarm display.
- Interface signals are set.
- NC not ready.
- NC Start disable in this channel.
Import the cycle again.
Switch control OFF - ON.
File %1 lost
%1 = Name of file
Due to a power failure, a file change could not be terminated properly. The file is lost.
- Alarm display.
- Interface signals are set.
- NC not ready.
- NC Start disable in this channel.
Import the file again.
Switch control OFF - ON.
Unknown NC card (%1/%2). Writing not possible.
%1 = actManufactorCode (manufacturer code read by the card)
%2 = actDeviceCode (memory code read by the card)
The NC card cannot be accessed because a valid write algorithm is not available for the
flash memory.
- Alarm display.
Use a compatible NC card or enter the new manufacturer code/device code in MD
$MN_PERMISSIVE_FLASH_TAB after consultation with SIEMENS.
Clear alarm with the Delete key or NC START.
Channel %1 value of the machine data %2%3 is too low
%1 = Channel number
%2 = MD identifier
%3 = If required, field index
The machine data $MC_MM_PROTOC_NUM_ETP_STD_TYP specifies the number of
default event types for the protocol users. However, more types are used than configured.
- Alarm display.
Increase machine data $MC_MM_PROTOC_NUM_ETP_STD_TYP.
Clear alarm with the Delete key or NC START.
Too many compile cycle alarms defined
Too many alarms are defined for the compile cycles. On powering up, the quantity was
exceeded when defining a new CC alarm.
- Alarm display.
Apart from reducing the number of CC alarms, no remedial measures are possible at the
present time. (contact SIEMENS AG, System Support for A&D MC products, Hotline (Tel.:
see alarm 1000)
Clear alarm with the Delete key or NC START.
1 Alarms