Siemens SINUMERIK 840D Series Diagnostics Manual page 418

Hide thumbs Also See for SINUMERIK 840D Series:
Table of Contents

Advertisement

1 Alarms
75600
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
75601
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
75605
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
75606
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
1-418
Channel %1 retrace support: wrong MD configuration. Error code %2
%1 = Channel number
%2 = Error code
The following errors were detected in the machine data of the retrace support function
when starting up:
Error code = 4
Machine data MM_NUM_CC_BLOCK_ELEMENTS must be increased.
Error code = 5
Insufficient compile cycle heap memory available.
Adjust machine data $MC_RESU_RING_BUFFER_SIZE,
$MC_RESU_SHARE_OF_CC_HEAP_MEM and
$MC_MM_NUM_CC_HEAP_MEM.
Error code = 6
The machine data $MN_ASUP_START_MASK and
$MN_ASUP_START_PRIO_LEVEL are not set correctly.
- Alarm display.
- NC Start disable in this channel.
Correct machine data.
Switch control OFF - ON.
Channel %1 block %2 invalid parameter in CC_PREPRE()
%1 = Channel number
%2 = Block number, label
Only the values –1, 0, 1 are valid for the parameter.
- Alarm display.
- Interpreter stop
Modify part program.
Clear alarm with the RESET key. Restart part program
Channel %1 retrace support: internal error, error code %2
%1 = Channel number
%2 = Error code
With this alarm, RESU-internal error states are displayed which, together with the trans-
ferred error number, provide information on the error cause and error location.
- Alarm display.
- NC Start disable in this channel.
If this error occurs, please contact us on the SINUMERIK Hotline of the SIEMENS AG,
specifying the error number.
Clear alarm with the RESET key. Restart part program
Channel %1 retraceable contour was shortened
%1 = Channel number
The block search buffer is full. Therefore the retraceable contour had to be shortened.
- Alarm display.
Adjust machine data $MC_RESU_RING_BUFFER_SIZE,
$MC_RESU_SHARE_OF_CC_HEAP_MEM and
$MC_MM_NUM_CC_HEAP_MEM.
Clear alarm with the Delete key or NC START.
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
 Siemens AG, 2002. All rights reserved
11.02

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840di seriesSinumerik 810d seriesSinumerik 840dSinumerik 840diSinumerik 810dSinumerik 840de ... Show all

Table of Contents