11.02
300402
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
300403
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
300404
Parameters:
Definitions:
 Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
System error in drive link. Error codes %1, %2
%1 = Error code 1
%2 = Error code 2
An internal software error or serious error condition has occurred which may be recover-
able by hardware reset. Troubleshooting can generally be performed only by Siemens
AG, System Support for A&D MC Products, Hotline (tel.: see alarm 1000).
In the error code combination (324,26), the calculation time allocation for the drive com-
munication subtask should be increased via the MD 10140
$MN_TIME_LIMIT_NETTO_DRIVE_TASK (possible up to 500 ms).
If the above-mentioned limit is exhausted and the alarm continues to occur, the MD 10150
$MN_PREP_DRIVE_TASK_CYCLE_RATIO=1 can be set additionally. Please note that
by reducing MD 10150, the time share of the preparation in the non-cyclic time plane is
reduced. This may lead to longer block cycle times.
- NC not ready.
- Channel not ready.
- NC Stop on alarm.
- NC Start disable in this channel.
- The NC switches to follow-up mode.
- Alarm display.
- Interface signals are set.
Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see
alarm 1000).
Switch control OFF - ON.
Axis %1 drive %2 drive software and drive MD with different version numbers
%1 = NC axis number
%2 = Drive number
The version number of the drive software (FDD/MSD) must correspond to the version
number stored in the drive machine data because the MD files for different software ver-
sions are not compatible.
- NC not ready.
- Channel not ready.
- NC Stop on alarm.
- NC Start disable in this channel.
- The NC switches to follow-up mode.
- Alarm display.
- Interface signals are set.
Please inform the authorized personnel/service department. After exchanging the drive
software, the drives must be installed and started up again. Any MD files that were saved
by the control running under the old version must no longer be used.
The old data can be saved with the installation and start-up tool and this data can also be
used again.
Clear alarm with the RESET key in all channels. Restart part program.
Axis %1 drive %2 drive MD contains different drive number
%1 = NC axis number
%2 = Drive number
In the drive MD file loaded in a drive there is a drive number which does not correspond to
this drive.