1 Alarms
Remedy:
Program Continuation:
10946
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
10947
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
10948
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
10949
Parameters:
Definitions:
1-120
Correct NC part program.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 curve table %3: no contour defined
%1 = Channel number
%2 = Block number, label
%3 = Number of curve table
No movement for the leading axis was programmed between CTABDEF and CTABEND.
A curve table is not permitted without a contour.
- Alarm display.
- Interface signals are set.
- Interpreter stop
- NC Start disable in this channel.
Correct the part program and start it again.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 curve table %3: contour not continuous
%1 = Channel number
%2 = Block number, label
%3 = Number of curve table
The contour in a curve table must be continuous. Incontinuity can occur, for example, as a
result of activating a transformation.
- Alarm display.
- Interface signals are set.
- Interpreter stop
- NC Start disable in this channel.
Correct the part program and start it again.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 curve table %3: position jump at end of period
%1 = Channel number
%2 = Block number, label
%3 = Number of curve table
A periodic curve table was defined in which the position of the following axis at the end of
the table was different to the position at the start of the table.
- Alarm display.
- Interface signals are set.
- Interpreter stop
- NC Start disable in this channel.
Correct the part program and start it again.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 curve table %3: missing master axis motion
%1 = Channel number
%2 = Block number, label
%3 = Number of curve table
A slave axis motion has been programmed without a master axis motion.
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
Siemens AG, 2002. All rights reserved
11.02