11.02
Remedy:
Program Continuation:
20061
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
20062
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
20063
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
20065
Parameters:
Definitions:
Reactions:
 Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
Check the operating steps to establish whether geometry axes really must be traversed,
otherwise switch over to the machine axes by activating the "WCS/MCS" key on the
machine control panel.
Clear alarm with the Delete key or NC START.
Channel %1 axis %2 cannot be traversed as orientation axis
%1 = Channel number
%2 = Axis name
The axis is not an orientation axis and can therefore not be traversed as an orientation
axis in JOG mode.
- Alarm display.
Register the axis as an orientation axis.
Clear alarm with the Delete key or NC START.
Channel %1 axis %2 already active
%1 = Channel number
%2 = Axis name, spindle number
The displayed axis is already traversing as a machine axis. Therefore, it cannot be oper-
ated as a geometry axis.
Traversing of an axis can take place in JOG mode through 2 different interfaces.
1. as a geometry axis: via the channel-specific interface DB 21 - DB 28, DBX12.6 or
DBX12.7
2. as a machine axis: via the axis-specific interface DB 31 - DB 48 DBX8.6 or DBX8.7
With the standard machine control panel, it is not possible to operate an axis as machine
axis and geometry axis at the same time.
- Alarm display.
Do not start the geometry axis until the traversing motion as machine axis has been con-
cluded.
Clear alarm with the Delete key or NC START.
Channel %1 axis %2 orientation axes cannot be traversed without transformation
%1 = Channel number
%2 = Axis name
An attempt was made to move an orientation axis in JOG mode without an active orienta-
tion transformation.
- Alarm display.
Activate an orientation transformation.
Clear alarm with the Delete key or NC START.
Channel %1 master spindle not defined for geometry axes in JOG mode
%1 = Channel number
The displayed axis is to be traversed as geometry axis in JOG mode with rotary feed, but
no master spindle has been defined from which the actual speed could be derived.
- Alarm display.
- Interface signals are set.
- Local alarm reaction.