11.02
Error code
Extension 1
Extension 2
Explanation
Remedy
Error code
Extension 1
Extension 2
Explanation
Remedy
Error code
Extension 1
Extension 2
Explanation
Remedy
 Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
0030H
0x01 ;Unsupported ROSCTR
0x02 ;Illegal ROSCTR
0x03 ;Job management "defective"
0x04 ;Incorrect PDUREF on acknowledgement
0x05 ;Acknowledgement not permitted at this time
0x06 ;Acknowledgement is not supported
0x07 ;Illegal PROTID
0x08 ;Illegal PARLG (uneven)
0x09 ;Buffer management "defective"
0x0A ;Illegal PI identifier (internal)
0x0B ;Illegal internal state of PI restart
0x0C ;Sequential circuit in WRITEDATA "defective"
0x0D ;Illegal parameter on REFRESH_PIZUST
NC drive number
Either irrecoverable communications errors were detected on the drive bus or the drive
software is no longer consistent.
The cause is either a faulty drive bus interface or a hardware error on the control module.
Check the drive bus cable and cable connections, perform remedial measures (check
shielding or ground connection). Replace the control module.
0031H
0x40 ;Illegal PDU length
0x41 ;Axes do not have the same PDU length
0x42 ;PDU length is not a word multiple
0x43 ;Axes do not have the same NC type
-
The NC has transferred illegal key data for communication via the drive bus. The cause is
probably either faults on the drive bus or a defective control module.
Replace the control module. Check cable connections, perform remedial measures
(check shielding or ground connection).
0032H
0x20 ;Job management "defective"
0x21 ;Illegal state in RESET_TRANSPO
0x22 ;Checksum incorrect more than 3 times
0x23 ;Receive PDU too long
0x24 ;State 6XX-Abort illegal
NC drive number
Either irrecoverable communications errors were detected on the drive bus or the drive
software is no longer consistent.
The cause is either a faulty drive bus interface or a hardware error on the control module.
Check the drive bus cable and cable connections, perform remedial measures (check
shielding or ground connection). Replace the control module.
1 Alarms