SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
Teach-in interruption: Log overflow
The Teach-in procedure was interrupted. Teach-in file is closed.
- Alarm display.
In the machine data 9606: $MM_CTM_SIMULATION_TIME_NEW_POS the value of the
update rate is to be increased by 100 to 200 ms.
Internal
Wrong position programmed for the spindle
A position beyond the range of 0 -359.999 has been programmed for a modulo axis.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Program a position in the 0 - 359.999 range.
Clear alarm with the RESET key. Restart part program
No measuring system available
SPCON, SPOS or SPOSA has been programmed.
These functions require at least one measuring system. According to MD: NUM_ENCS
the machine axis/spindle has no measuring system.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Retrofit a measuring system.
Clear alarm with the RESET key. Restart part program
No spindle stop for a block change
The displayed spindle has been programmed as spindle or as axis even though a posi-
tioning operation is still running from the previous block (with SPOSA ... spindle position-
ing beyond block limits).
Example: N100 SPOSA [2] = 100 etc., N126 S2 = 1000 M2 = 04Error, if the spindle S2is
still running from block N100!
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Before programming the spindle/axis again using the SPOSA instruction, a WAITS com-
mand should be activated in order to wait for the programmed spindle position.
Example: N100 SPOSA [2] = 100 etc., N125 WAITS (2) N126 S2 = 1000 M2 = 04
Clear alarm with the RESET key. Restart part program
Reference mark not found
When referencing, the spindle turned through a greater distance than given in the axis-
specific machine data 34,060 REFP_MAX_MARKER_DIST, without receiving a reference
mark signal. The check is performed for spindle positioning with SPOS or SPOSA when
the spindle has not previously run with speed control (S=...).
1 Alarms
1-445