Siemens SINUMERIK 840D Series Diagnostics Manual page 80

Hide thumbs Also See for SINUMERIK 840D Series:
Table of Contents

Advertisement

1 Alarms
Remedy:
Program Continuation:
8041
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
8044
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
8045
Definitions:
Reactions:
Remedy:
Program Continuation:
1-80
Please inform the authorized personnel/service department. For retrofitting the option,
please refer to your machine manufacturer or to a sales representative of SIEMENS AG,
A&D MC.
Clear alarm with the Delete key or NC START.
Axis %1: MD %2 reset, corresponding option not sufficient
%1 = Axis number
%2 = String: MD identifier
All of the axes selected in the machine data of the assigned option are used. Safety func-
tions have been selected for too many axes in the axial machine data.
The alarm can be reprogrammed in the MD ALARM_REACTION_CHAN_NOREADY
(channel not ready).
- Alarm display.
- Interface signals are set.
- NC Start disable in this channel.
- NC Stop on alarm.
- Mode group not ready.
- Channel not ready.
- Channel not ready.
-
Switch control OFF - ON.
Option for IPO cycle time %1 ms not set
%1 = Impermissible IPO cycle time
The option for activation of an IPO cycle time of %1 ms has not been set.
Option - Permiss. IPO cycle time:
• Option-free >= 8ms
• 1. 1st step >= 6ms
• 2. 2nd step >= 4ms
• 3. 3rd step >= 2ms
• 4. 4th step <2ms
- Alarm display.
- Interface signals are set.
- NC Start disable in this channel.
- Interpreter stop
• Buy option
• Increase IPO cycle time (e.g. via MD IPO_SYSCLOCK_TIME_RATIO)
Switch control OFF - ON.
Option for selected cycle settings not set
The option for the 810D Powerline for activation of the same current/speed/position con-
troller/IPO cycle time grid as with the 840D is not set. Without the option, only the set val-
ues of the 810D Standard are permitted.
- Alarm display.
- Interface signals are set.
- NC Start disable in this channel.
- Interpreter stop
• Buy option
• Set (current/speed controller) cycle times to 810D default values.
Switch control OFF - ON.
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
 Siemens AG, 2002. All rights reserved
11.02

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840di seriesSinumerik 810d seriesSinumerik 840dSinumerik 840diSinumerik 810dSinumerik 840de ... Show all

Table of Contents