1 Alarms
301709
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
301710
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
301711
Parameters:
Definitions:
Reactions:
Remedy:
1-542
Axis %1 drive %2 submodule with integrated linearization invalid
%1 = NC axis number
%2 = Drive number
If a submodule with integrated linearization is used, all submodules on the module must
use the integrated linearization. A submodule with integrated linearization was found.
However, not all submodules have this linearization.
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- NC Stop on alarm.
- Alarm display.
- Interface signals are set.
Replace the submodule.
Switch control OFF - ON.
Axis %1 drive %2 resolution SSI motor measuring system invalid
%1 = NC axis number
%2 = Drive number
The configuration of the motor measuring system for an SSI encoder is incorrect:
MD_1022 $MD_ENC_ABS_RESOL_MOTOR must not be 0.
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- NC Stop on alarm.
- Alarm display.
- Interface signals are set.
• Set MD_1022 $MD_ENC_ABS_RESOL_MOTOR to the correct value:
• Rotary encoder: Singleturn resolution (increments per revolution).
• Linear encoder: Resolution of an increment (in nanometers).
Switch control OFF - ON.
Axis %1 drive %2 transmission length SSI motor measuring system invalid
%1 = NC axis number
%2 = Drive number
The configuration of the motor measuring system for an SSI encoder is incorrect:
MD_1028 $MD_NO_TRANSMISSION_BITS (SSI transmission length) is less than the
number of all parameterized bits in MD_1021 $MD_ENC_ABS_TURNS_MOTOR (multi-
turn), MD_1022 $MD_ENC_ABS_RESOL_MOTOR (singleturn) and MD_1027
$MD_ENC_CONFIG bit 14 (alarm bit) and MD_1027 $MD_ENC_CONFIG bit 12 (parity
bit).
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- NC Stop on alarm.
- Alarm display.
- Interface signals are set.
• Set parameters correctly for all associated machine data:
• MD_1028 $MD_NO_TRANSMISSION_BITS (SSI transmission length): number of bits
in an SSI protocol, including all bits, such as alarm bit/parity bit
• MD_1021 $MD_ENC_ABS_TURNS_MOTOR (multiturn): number of resolvable revolu-
tions
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
 Siemens AG, 2002. All rights reserved
11.02

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840di seriesSinumerik 810d seriesSinumerik 840dSinumerik 840diSinumerik 810dSinumerik 840de ... Show all

Table of Contents