Siemens SINUMERIK 840D Series Diagnostics Manual page 266

Hide thumbs Also See for SINUMERIK 840D Series:
Table of Contents

Advertisement

1 Alarms
17502
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
17503
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
17510
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
17600
Parameters:
Definitions:
1-266
Channel %1 block %2 indexing axis %3 with Hirth tooth system stop is delayed
%1 = Channel number
%2 = Block number, label
%3 = Axis name
For the indexing axis, the 'Hirth tooth system' function is activated and the override has
been set to 0 or another stop condition (e.g. VDI interface signal) is active. Since it is pos-
sible to stop only on indexing axes, the next possible indexing position is approached.
The alarm is displayed until this position is reached or the stop condition is deactivated.
- Alarm display.
Wait until the next possible indexing position is reached or set override > 0 or deactivate
another stop condition.
Alarm display showing cause of alarm disappears. No further operator action
Channel %1 block %2 indexing axis %3 with Hirth tooth system and axis not refer-
enced
%1 = Channel number
%2 = Block number, label
%3 = Axis name
The 'Hirth tooth system' function is activated for the indexing axis and the axis is to be tra-
versed although it is not referenced.
- Alarm display.
Reference axis.
Clear alarm with the Delete key or NC START.
Channel %1 block %2 invalid index for indexing axis %3
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
The programmed index for the indexing axis is beyond the position table range.
Example:
Perform an absolute approach of the 56th position in the list allocated via the axis-specific
machine data 30500 INDEX_AX_ASSIGN_POS_TAB with the 1st positioning axis, the
number of positions is e.g. only 40 (MD 10900 INDEX_AX_LENGTH_POS_TAB_1 = 40).
N100 G.. U=CAC (56)
- Alarm display.
- Interface signals are set.
- Interpreter stop
- NC Start disable in this channel.
Program the indexing axis position in the NC part program in accordance with the length
of the current position table, or add the required value to the position table and adjust the
length of the list.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 preset on transformed axis %3 not possible
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
The displayed axis is involved in the current transformation. This means that is it not pos-
sible to set the actual value memory (preset) for this axis.
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
 Siemens AG, 2002. All rights reserved
11.02

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840di seriesSinumerik 810d seriesSinumerik 840dSinumerik 840diSinumerik 810dSinumerik 840de ... Show all

Table of Contents