Siemens SINUMERIK 840D Series Diagnostics Manual page 159

Hide thumbs Also See for SINUMERIK 840D Series:
Table of Contents

Advertisement

11.02
Definitions:
Reactions:
Remedy:
Program Continuation:
14015
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14016
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14017
Parameters:
Definitions:
 Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
The selected part program is not in the NCK memory or the access authorization for the
program selection is from a higher level than the current control status.
During creation, this program received the protection level of the NC control which was
active at the time.
As of SW 5, when a program is edited on the MMC, it can no longer be started with NC
Start.
- Alarm display.
Reload the program in the NCK memory or check and correct the name of the directory
(workpiece overview) and the program (program overview) and reselect.
Clear alarm with the Delete key or NC START.
Channel %1 block %2 program %3 is not enabled
%1 = Channel number
%2 = Block number, label
%3 = Program name
The user has no execution authorization for the file, the file is not released.
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
Please inform the authorized personnel/service department. Change user authorization,
release file.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 error when calling the subroutine via M/T function
%1 = Channel number
%2 = Block number, label
The following conflict was detected in a subprogram call per M or T function:
In the block referenced by parameter %2:
• An M or T function replacement has already been activated
• A modal subprogram call is active
• A subprogram return jump is programmed
• An end of program is programmed
• An M98 subprogram call is active (only in external language mode)
• T function replacement by D function programming in the same part program line is not
possible with active TLC (G43/G44) in ISO2 system.
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
An M or T function replacement is only possible if a subprogram call or return jump has
not already been performed as a result of other program constructs. The part program
must be corrected accordingly.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 syntax error when calling the subroutine via M function
%1 = Channel number
%2 = Block number, label
When calling M code subroutine with parameter transfer, an illegal syntax was detected:
• Address extension not programmed as a constant.
• M function value not programmed as a constant.