IBM Multiprise 3000 S/390 Installation Manual page 131

Enterprise
Table of Contents

Advertisement

5 Performing a power-on reset
1. Select Options from the action bar.
2. Select Exit from the pull-down.
3. Open Task List from the Views area
4. Open CPC Recovery from the Task List
Work Area
5. Open Groups from the Views area
6. Select CPC from the Groups Work Area
7. Drag and drop the selected object on
Power-On-Reset in the CPC Recovery
area
The Power-on Reset panel displays.
8. Under the title of Mode, select ESA/390
9. Under the title of Input/output
configuration data sets (IOCDS), select
the data set you just built.
10. Select OK.
The Change Storage Sizes panel displays.
11. Select OK.
The Confirm the Action panel displays.
12. Select Power-on reset
A power-on reset in progress panel
displays while the power-on reset is
performed. A power-on reset takes
approximately 5 minutes to complete.
When complete, a message displays
confirming the function is complete.
13. Select OK on the Power-on Reset
message panel.
Chapter 6. Completing the Installation
6-53