Servicing The Lift Control Valve (Machine Serial Numbers Below 311000000) - Toro Groundsmaster 3280-D Service Manual

Hide thumbs Also See for Groundsmaster 3280-D:
Table of Contents

Advertisement

Servicing the Lift Control Valve (Machine Serial Numbers below
311000000)
g230842
1.
Detent ball
2.
Spring
3.
Gasket
4.
O-ring
5.
Screw
6.
Washer
7.
Screw and lock washer (2 each)
8.
Spool
9.
Plug
Disassembly the Lift Control Valve
Hydraulic System: Service and Repairs
10.
Poppet stop
11.
Poppet
12.
End cap
13.
Spacer
14.
Adapter plug
15.
O-ring
16.
Detent plug
17.
Spring
18.
O-ring
1. Plug all ports and clean the outside of control valve.
2. Remove 2 screws and lock washers (item 7 in
cap to control valve. Remove end cap.
3. Remove screw (item 5 in
control valve.
4. Carefully slide spool (item 8 in
Figure 104
19.
20.
21.
22.
23.
24.
25.
Figure
104), spacer, spring, and washer from
Figure
104) from housing bore.
Page 5–130
Detent plunger
Spring
O-ring
Lockout seat (black)
O-ring
O-ring
Lockout seat (silver)
Figure
104) that secure end
Groundsmaster
®
3280-D/3320
05138SL Rev B

Advertisement

Table of Contents
loading

This manual is also suitable for:

Groundsmaster 3320

Table of Contents