Testing the Lift Control Valve Solenoid Valve Coil (continued)
Electrical System: Testing the Electrical Components
4. Use a multimeter (ohms setting), measure the resistance between the 2
connector terminals on the solenoid valve coil. The correct resistance for
the solenoid coil is identified in the
(page
6–64).
Solenoid Valve Coil Specifications Table
Solenoid Valve Coil
SV1
35.8 mm (1.41 inches)
SV2
46.7 mm (1.84 inches)
5. If the solenoid coil resistance is incorrect, replace the solenoid coil; refer to
the
Lift Control Valve Solenoid Valve Coils (Machine Serial Number above
311000000) (page
6. After testing the coils, connect the wire harness electrical connector to the
solenoid valve coil.
Solenoid Valve Coil Specifications Table
Diameter
36.3 mm (1.43 inches)
49.9 mm (1.96 inches)
6–76).
Page 6–64
Height
Resistance
8.8 ohms
7.1 ohms
Groundsmaster
®
05138SL Rev B
3280-D/3320