Model 2700 PROFIBUS Block Parameters
F.3.2

Physical block views

Table F-4 shows the physical block views.
Table F-4
Physical block views
OD
Parameter Mnemonic
Index
Standard Parameters
16
BLOCK_OBJECT
17
ST_REV
18
TAG_DESC
19
STRATEGY
20
ALERT_KEY
21
TARGET_MODE
22
MODE_BLK
23
ALARM_SUM
Overall sum of bytes in View Object
OD
Parameter Mnemonic
Index
Standard Parameters
29
DIAGNOSIS
Overall sum of bytes in View Object
(+ 13 Standard parameters bytes)
F.4

Transducer block 1 (measurement, calibration, and diagnosis)

Table F-5 shows the parameters for transducer block 1.
Table F-5
Transducer block 1 parameters
Index
Parameter Mnemonic
Standard PA parameters
0
BLOCK_OBJECT
1
ST_REV
2
TAG_DESC
3
STRATEGY
4
ALERT_KEY
5
TARGET_MODE
6
MODE_BLK
7
ALARM_SUM
Standard Flow Transducer
block Parameters
154
Definition
This object contains the
characteristics of the block
A block has static block
parameters, that are not changed
by the process. Values are
assigned to this parameter during
the configuration of optimization.
The value of ST_REV increases
by 1 after every change of a static
block parameter.
Every block can be assigned a
textual TAG description. The
TAG_DESC must be
unambiguous and unique in the
field bus system.
Grouping of function block. The
STRATEGY field can be used to
group blocks.
This parameter contains the
identification number of the plant
unit.
This parameter contains desired
mode normally set by a control
application of an operator. The
modes are valid alternatively only,
i.e. only one mode can be set at
one time. A write access to this
parameter with more than one
mode is out of the range of the
parameter and has to be
rejected.
This parameter contains the
current mode and the permitted
and normal mode of the block.
This parameter contains the
current states of the block alarms.
View 1
2
3
8
13
View 1
4
4+13
Message
Data Type/
Size
Type
Structure
RECORD
DS-32
20
SIMPLE
Unsigned16
2
SIMPLE
OCTET
32
STRING
SIMPLE
Unsigned16
2
SIMPLE
Unsigned8
1
SIMPLE
Unsigned8
1
RECORD
DS-37
3
RECORD
DS-42
8
View 2
View 3
View 4
View 2
View 3
View 4
Store
Default
Access
Enumerated List of
/Rate
Value
Values / Range
(HZ)
CSt
----
R
NA
N
0
R
NA
S
' '
R/W
NA
S
0
R/W
NA
S
0
R/W
NA
S
AUTO
R/W
AUTO (0x08)
(0x08)
D
---
R
NA
D
0,0,0,
R
NA
0
Model 2700 Transmitter with PROFIBUS-PA
Modbus
Register /
Coil
NA
NA
NA
NA
NA
NA
NA
NA