Emerson Micro Motion 2700 Configuration And Use Manual page 165

With profibus-pa
Hide thumbs Also See for Micro Motion 2700:
Table of Contents

Advertisement

Model 2700 PROFIBUS Block Parameters
Table F-5
Transducer block 1 parameters (continued)
Index
Parameter Mnemonic
59
SNS_VolTotalUnits
(DD Name: Volume Total/Inv
Units)
60
SNS_ResetMassInv
(DD Name: Reset Mass
Inventory)
61
SNS_ResetVolInv
(DD Name: Reset Volume
Inventory)
Gas Process Variables
62
SNS_EnableGSV
(DD Name: Enable Gas Std
Volume Flow And Total)
63
SNS_GSV_GasDens
(DD Name: Gas Std Density)
64
SNS_GSV_VolFlow
(DD Name: Gas Std Volume
Flow Rate)
65
SNS_GSV_VolTot
(DD Name: GSV Total)
66
SNS_GSV_VolInv
(DD Name: GSV Inventory)
67
SNS_GSV_FlowUnits
(DD Name : GSV Flow Units)
68
SNS_GSV_TotalUnits
(DD Name: GSV Total/Inv
Units)
69
SNS_GSV_FlowCutoff
(DD Name: Gas Std Vol Flow
Cutoff)
70
SNS_ResetGSVolTotal
(DD Name: Reset Gas Std
Volume Total)
71
SNS_ResetAPIGSVInv
(DD Name: Reset Gas Std
Volume Inventory)
72
FRF_StartMeterVer
DD Name: Start On-Line Meter
Verification)
73
FRF_MV_Index
74
FRF_MV_Counter
75
FRF_MV_Status
76
FRF_MV_Time
77
FRF_MV_LPO_Norm
78
FRF_MV_RPO_Norm
79
FRF_MV_FirstRun_Time
80
FRF_MV_Elapse_Time
81
FRF_MV_Time_Left
Configuration and Use Manual
Definition
Message
Type
Standard or special volume total
ENUM
or mass inventory unit
Reset Mass Inventory ("On" =
METHOD
Reset, "Off" = N/A)
Reset Volume Inventory ("On" =
METHOD
Reset, "Off" = N/A)
Enable/Disable Gas Standard
ENUM
Volume Flow and Totals
Gas Density used to calculate
VARIABLE
Reference Volume Gas Flow and
Totals
Reference Volume Gas Flow
VARIABLE
Rate (not valid when API or ED is
enabled)
Reference Volume Gas Total (not
VARIABLE
valid when API or ED is enabled)
Reference Volume Gas Invnetory
VARIABLE
(not valid when API or ED is
enabled)
Gas Standard Volume Flow
ENUM
Engineering Units
Gas Standard Volume Total and
ENUM
Inventory Engineering Units
Gas Standard Volume Low Flow
VARIABLE
Cutoff
Reset Gas Standard Volume
Method
Total ("On" = Reset, "Off" = N/A)
Reset API/GSV Inventory ("On" =
Method
Reset, "Off" = N/A)
Start On-Line Meter Verification
VARIABLE
FCF Datalog Index
VARIABLE
FCF Datalog Item 1: Run Number VARIABLE
FCF Datalog Item 5: Status
VARIABLE
Abort States are compressed to
fit in 3 bits
FCF Datalog Item 2: Time
VARIABLE
Initiated (in running seconds)
FCF Datalog Item 3: LPO
VARIABLE
Normalized Data
FCF Datalog Item 4: RPO
VARIABLE
Normalized Data
MV Timers: Time Until First Run
VARIABLE
in Hours
MV Timers: Time between each
VARIABLE
run after the first run initiated in
hours
MV Timers: Time left until next
VARIABLE
run in hours
Data Type/
Size
Store
Default
Access
Structure
/Rate
Value
(HZ)
Unsigned16
2
S
l/s
R
Unsigned8
1
D
-
R/W
Unsigned8
1
D
-
R/W
Unsigned8
1
S
0x00
R/W
FLOAT
4
S
0.075
R/W
2
lb/ft3
101
5
D/20
0
R
101
5
D/20
0
R
101
5
D/20
0
R
Unsigned16
2
S
SCFM
R/W
Unsigned16
2
S
SCF
R
FLOAT
4
S
---
R/W
Unsigned8
1
S
--
R/W
Unsigned8
1
S
0x00
R/W
Unsigned8
1
D
0x00
R/W
Unsigned16
2
D
0x00
R/W
Unsigned16
2
N-CP
0x00
R
Unsigned16
2
N-CP
0x00
R
Unsigned32
4
N-CP
0x00
R
FLOAT
4
N-CP
0x00
R
FLOAT
4
N-CP
0x00
R
FLOAT
4
N-CP
0x00
R/W
FLOAT
4
N-CP
0x00
R/W
FLOAT
4
D
0x00
R
Enumerated List of
Modbus
Values / Range
Register /
Coil
0000 = None
R-0046
1034 = m3
1036 = cm3
1038 = l
1043 = ft3
1048 = gal
1049 = ImpGal
1051 = bbl
1641 = Beer bbl
0X00 = None
Coil – 0192
0X01 = Reset
0x00 = None
Coil – 0193
0X01 = Reset
0x00 = disabled
Coil-0078
0x01 = enabled
Density Sensor limits
R-0453-
0454
N/A
R-0455-
0456
N/A
R-0457-
0458
N/A
R-0459-
0460
1360 = SCFM
R-2601
1361 = SCFH
1605 = SCFD
1522 = Nm3/s
1523 = Nm3/m
1524 = Nm3/h
1525 = Nm3/d
1527 = Sm3/s
1528 = Sm3/m
1529 = Sm3/h
1530 = Sm3/d
1532 = NL/s
1533 = NL/m
1534 = NL/h
1535 = NL/d
1537 = SL/s
1538 = SL/m
1539 = SL/h
1540 = SL/d
1604 = SCFS
0000 = None
R-2602
1053 = SCF
1521 = Nm3
1526 = Sm3
1531 = NL
1536 = SL
Must be >=0.0
R-461-462
0x00 = No effect
Coil-0063
0x01 = Reset
0x00 = No Effect
Coil-0194
0x01 = Reset
0x00 = No Effect
Coil-0190
0x01 = Start On-Line
Meter Verification
(0-19, 0 = most
R-2984
recent run)
R-2985
Bit7 = FCF pass/fail,
R-2986
Bits6-4 = state,
Bits3-0 = Abort code
N/A
R-2987–
2988
N/A
R-2989–
2990
N/A
R-2991–
2992
N/A
R-2993–
2994
N/A
R-2995–
2996
N/A
R-2997–
2998
157